Our analytical services can be used in the following application areas:
Sample application | Analysis parameter | DIN standard | Unit |
Waste water contamination | Hydrocarbons | DIN 38409 - H18 | ppm |
Laboratory test of waste water | Elimination test of hazardous substances in waste water |
| %/ppm |
Waste water analysis according to appendix 40 of administrative regulations for waste water (Abw.-VwV) | See administrative regulations, appendix 40 |
|
|
Definition of the chemical oxygen requirements | COD | DIN 38409 - H18 | >ppm |
Degreasing bath contamination | Hydrocarbons | DIN 38409 - H18 | ppm |
Precipitation / flocculation behaviour according to jar test | COD, turbidity |
| % COD elimination / FAU turbidity |
Metallic content guideline | F-AAS |
| % / ppm / ppb> |
Inspection of hazardous substances | Determination of flashpoint, nitrosamine analysis | EN 22719 | °C |
Poisonous substances | AOX content | DIN 38409 - H18 | ppm |
Sample application | Analysis parameter | DIN standard | Unit |
Material analysis | ESCA, electron spectroscopy, chemical analysis |
|
|
Anti-corrosion capacity |
| DIN 51360 |
|
Corrosive erosion of steel and aluminium | Material erosion | DB AG work instructions | mg/cm2 |
Paint compatibility |
| DEKRA work instructions |
|
Sample application | Analysis parameter | DIN standard | Unit |
Determination of orthophosphoric acid |
|
| % |
Dermatological test | Skin irritation characteristics |
|
|
Emulsification capacity |
| DEKRA work instructions | mg oil/L |
Performance comparison of dishwashing detergents | Start-up behaviour, deposits, discolouration | DIN 44990 |
|
Performance comparison of surface cleaners and care products | Gliding behaviour, swelling and shrinkage, colour changes on selected floor surfaces | DIN 18032 |
|
Phosphate content in cleaning agents | Orthophosphate |
| % |
Physical characteristics | Viscosity, foaming, density, conductivity of liquids, surface tension, wetting behaviour | DIN 53902 | cm mPas g/mL mS/cm |
Product characterisation | pH value, determination of alkalinity of nitrogen | according to Keijdal | % / g/L etc. |
Product characterisation of solvent mixtures | SSpecific resistance |
| kO*m |
Product identification | Refraction value (nD20, nD25) IR analysis |
|
|
Quality check of raw materials | e.g. P2O5 content |
| % |
Quantification of solvent mixtures | Gas chromatography, GC/MS vacuum distillation, azeotropic distillation | Rotary evaporator |
|
Quantification of water-based mixtures | Karl-Fischer titration | Titrator | % |
Cleaning efficiency |
| ÖNORM 5106/7.2 (Austrian standard) | Remission |
Storage behaviour of raw materials and products | Turbidity point, clear melting point, long-term storage test |
| °C |
Rolling oil inspection | Simulated distillation, saponification number | ASTM D 2887 | %mg/g |
Anionic / cationic surfactants | Epton titration | DIN 2271 | % |
Resistance to high temperatures |
| DEKRA work instructions |
|
Definition of clear melting point | Temperature |
| °C |
Want to learn more? We look forward to hearing from you under +49 (0) 209 95899-0, or by e-mail under info@robotchemie.de.